We would like to introduce the HV1600-2 Speed. The Unit has two
speed settings, low/high. On low the unit performs like an HV1000
with 900 cfm of air flow.
On high the unit does 1600 cfm of air flow.
Unlike other systems, the HV series requires no maintenance. The
fan motors of the HV1600 are of extremely high quality and are built to
last. The unit is available as a standard with R-22 insulated
doors. There is an option for R-38 insulation. The HV series
of fans are insulated and when not in use form an air tight seal between
your attic and living space. There is no other unit
available that boasts these levels of insulation and protection.
As an additional quality control method, every single unit is tested and
run at the factory for 24 hours prior to shipping, a commitment to a
great product which we can say is Made In The Usa.
House Size:
HV1600™
Typical
24" Fan
Typical
30" Fan
Air Flow:
900 cfm/low
3000 cfm
6000 cfm
1600 cfm/high
1500 Square Ft.:
7.5 minutes/high
4
minutes
2
minutes
2000 Square Ft.:
10 minutes/high
5.33
minutes
2.67
minutes
2500 Square Ft.:
12.5 minutes/high
6.67
minutes
3.33
minutes
For 2006 The HV1600 is available in the following models:
Grille: The HV system includes a 24"
x 14" white return air grille. The outside diameter of the grille
measures 25 3/4" x 15 3/4". The rough opening of the grille
measures 23 1/4" x 13 7/8".
Controls: The units come standard with RF remote controls, which
have a range of approximately 30'. The units can also be hard
wired to a wall switch. Both controls together can also be used.
However, on/off and speed functions if turned on with the remote must be
used with the remote and vice versa with the wall switch for the
duration the fan is running.
Wireless Remote Control (RC) for the
HV1600: The wireless remote control is a very popular item as
there is no need to run electrical line down a wall for the switch,
although if desired once can also be used with this unit.
The dedicated
remote control system offers the user a simplified 110 volt powered
remote control. The system includes a
hand-held transmitter, which operates on a 12-volt battery (included),
a receiver which has been built into the fan. The transmitter features a signal operating light that goes on
when the ON or OFF buttons are depressed. The controls offer 256 unique
security codes that are factory programmed into the system allowing
multiple remote control units in the same room or building. The systems
operating distance is 60' and is not
restricted to "line-of-sight" applications because the system uses radio
frequency control. It operates on the R.F.
frequency of 303.875 MHz. The control is UL listed and is FCC certified
in the U.S. and I.S.C. certified in Canada.
Net Free Area Defined: For every 750 cfm of airflow, it is
recommended that there be a minimum of 1 sq. ft. of attic venting, i.e.
roof vents, gable vents, soffit vents, ridge vent. This will allow
the air flow of the fan's exhaust air into the attic the ability to flow
out of the home freely.
To calculate your net free area: - Count and add up your total number of
vents in feet. If your vent(s) are screened take approx. 1/2 away
from your total. For example:
You have four 1 sq. ft vents, and they are screened. You
would have a 4 sq ft gross of venting, however since the screens will
block air flow, you would need to subtract approximately 2 sq. ft of
venting from your gross, giving you a 2 sq. ft net free area.
Warranty: The unit comes standard with a 3 year limited warranty.
Wiring The HV1600 as of 12/26/2005:
All HV1600 models are now being shipped with line cords. A
standard household 120 VAC outlet is required, within 6' of the unit.
Once the framed in area has been prepared, Simply plug the fan in and
its ready to start cooling.
Download HV1600 Manual Add-on (requires pdf reader)
Wiring The HV1600 Gold 2005/previous models:
The HV1600 Gold requires a constant source of power. Because the
doors are motorized, they need power to open and power to close.
(Fan ON/OFF operation is controlled internally.) There are four
wires in the electrical box: WHITE, BLACK, a YELLOW and a BLUE.
The WHITE should be connected Line Neutral,
115 VAC 60 Hz
The BLACK should be connected to Line Hot, 115 VAC 60 Hz
Connect ground wire to screw in electrical box.
With just the BLACK and WHITE wires connected to power, the HV1600 Gold
will be fully functional with the hand held remote control unit.
The YELLOW and BLUE wires can be used to provide "hard wired" control.
The BLUE wire will provide ON/OFF control and the YELLOW wire can
provide HIGH or LOW speed control with two separate switches, one for
each function.
Note that both sets of buttons on the remote control are marked ON/OFF.
The top pair will activate and deactivate the fan. The bottom pair
turn the HIGH speed on or off. If the HV 1600 Gold R has been
"hard wired" to a wall mounted ON/OFF switch or HIGH/LOW switch or both,
note that both the wall switch and the remote control switch cannot be
used at the same time.
If the wall mounted ON/OFF switch is in the
ON position, the ON/OFF buttons on the remote control will NOT function.
If the wall mounted HIGH/LOW switch is set
to HIGH, the HIGH/LOW buttons on the remote control will not function
Note that when any of the buttons on the
remote control are pushed, the Red indicator light should momentarily
flash. If it doesn't and the system fails to operate, first check
that the optional "hard wired" wall switches are set to the OFF position
and then change the battery in the handheld remote control device.